Comparison of X-Ray Absorption in Mandibular Tissues and Polymeric Tissue-Equivalent Materials Using PHITS Monte Carlo Simulations

Comparison of X-Ray Absorption in Mandibular Tissues and Polymeric Tissue-Equivalent Materials Using PHITS Monte Carlo Simulations

Author(s): Jackson Lotery*

Department of Computer Engineering, University of Groningen, CP Groningen, Netherlands

*Corresponding Author:
Jackson Lotery
Department of Computer Engineering
University of Groningen
CP Groningen, Netherlands
E-mail: jacksonoteryl@dri.edu

Received: 01 November, 2024, Manuscript No. ijcmi-24-156559; Editor assigned: 02 November, 2024, Pre QC No. P-156559; Reviewed: 18 November, 2024, QC No. Q-156559; Revised: 23 November, 2024, Manuscript No. R-156559; Published: 30 November, 2024, DOI: 10.4172/2376-0249.1000986

Citation: Lotery J. (2024) Comparison of X-Ray Absorption in Mandibular Tissues and Polymeric Tissue-Equivalent Materials Using PHITS Monte Carlo Simulations. Int J Clin Med Imaging 11: 986.

Copyright: © 2024 Lotery J. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution and reproduction in any medium, provided the original author and source are credited.

Brief Report

X-ray absorption in mandibular tissues is a critical factor in diagnostic imaging and treatment planning in dentistry and maxillofacial applications. To improve the accuracy of simulations and experimental models, tissue-equivalent polymeric materials are often used as substitutes for biological tissues. This study aims to compare the X-ray absorption characteristics of mandibular tissues and these polymeric materials using PHITS Monte Carlo simulations. Monte Carlo simulations provide a detailed and precise approach to modeling X-ray interactions with matter. Using PHITS, we simulated X-ray absorption in mandibular tissues, including bone and soft tissue, and compared these with commonly used polymeric substitutes. The simulation incorporated realistic energy ranges relevant to dental radiography, taking into account tissue composition and density.

The results revealed that polymeric tissue-equivalent materials exhibit absorption properties that closely match those of actual mandibular tissues, particularly within the diagnostic X-ray energy range. However, slight variations were observed in the absorption coefficients, influenced by differences in elemental composition and density. These discrepancies highlight the importance of selecting the appropriate polymeric materials for specific applications to ensure accurate dosimetric and imaging outcomes. This comparison underscores the utility of Monte Carlo simulations in validating and optimizing tissue-equivalent materials for medical and dental applications. The findings provide valuable insights for developing more accurate models in radiological research and clinical practice. Further studies are recommended to explore the behavior of these materials under varying conditions and energy ranges to enhance their applicability. The integration of advanced simulation tools like PHITS offers a pathway for improving the precision of diagnostic imaging and therapeutic interventions in dentistry and beyond [1,2].

Keywords

X-ray absorption; Polymeric materials; Maxillofacial applications

Acknowledgement

None.

Conflict of Interest

None.

References

[1] Gokcekuyu Y, Ekinci F, Buyuksungur A, Guzel MS and Acici K, et al. (2024). Comparison of X-Ray Absorption in Mandibular Tissues and Tissue-Equivalent Polymeric Materials Using PHITS Monte Carlo Simulations.Appl Sci 14(23) 10879.

Google Scholar, Crossref, Indexed at

[2] Pehlivanlı A and Bölükdemir MH (2022). “Investigation of the effects of biomaterials on proton Bragg peak and secondary neutron production by the Monte Carlo method in the slab head phantom.”Appl Radiat Isot 180 110060.

Google Scholar, Crossref, Indexed at

flyer Image Awards Nomination
Indexing and Archiving
A generic square placeholder image with rounded corners in a figure.
All published articles are assigned to Digital Object Identifier (DOI)- CrossRef.
A generic square placeholder image with rounded corners in a figure.
All published articles of this journal are included in the indexing and abstracting coverage of:
Google Scholar citation report
Citations : 293

International Journal of Clinical & Medical Images received 293 citations as per Google Scholar report