international journal of clinical & medical images, clinical journals, medical journals, omics international, international journals, open access publication, scientific journals, free online medical journals, peer reviewed online journals, research, free online scientific articles
PHONE
+44-7482-878921

International Journal of Clinical & Medical Images

2376-0249

Clinical Image - International Journal of Clinical & Medical Images (2014) Volume 1, Issue 3

Left Atrial Appendage Thrombus on an Amplatzertm Cardiac Plug Device

Left Atrial Appendage Thrombus on an Amplatzertm Cardiac Plug Device

Author(s): Int J Clin Med Imaging 2014

The left atrial appendage (LAA) is an embryonic remnant of the left atrium (LA) with variable shape, located in the atrioventricular sulcus. It communicates with the LA through an oval ostium between the left superior pulmonary vein and the left ventricle. In patients with atrial fibrillation (AF) and high risk of cardio-embolic stroke, oral anticoagulation (OAC) is the gold standard of therapy. However, there is a subset of patients in whom long term OAC is contraindicated, intolerable or non-feasible due to poor compliance. Since 90% of embolic strokes in patients with non-valvular AF originate from a thrombus in the LAA, the hypothesis of stroke prevention with amputation or obliteration of the LAA was developed. Several devices were developed to achieve this goal one of them being the Amplatzer cardiac plug (ACP), delivered percutaneously with transeptal access to the LA. The picture shown is a short axis of the aortic valve at midesophageal level on a transesophageal echocardiogram of a patient who underwent ACP placement. A thrombus (dashed arrow) is evidenced emerging from the ACP device (arrow) within the LAA. In animal models, endothelialization of ACP was achieved by 90 days, based on this observation we recommend at least 3 months of anticoagulation when possible after device placement to decrease risk of device thrombus formation while allowing endothelialization of the device to occur. Although a promising approach, clinicians should take into account that as a foreign body inside the heart, these devices may trigger the formation of new thrombus in the LA, which may itself be the source of cardioembolic strokes. Well-designed clinical trials are still required to conclude the ideal patients that will benefit from these devices.

Corresponding author
Giovanni Davogustto

Department of internal medicine
University of Texas
USA

flyer Image Awards Nomination
Indexing and Archiving
A generic square placeholder image with rounded corners in a figure.
All published articles are assigned to Digital Object Identifier (DOI)- CrossRef.
A generic square placeholder image with rounded corners in a figure.
All published articles of this journal are included in the indexing and abstracting coverage of:
Google Scholar citation report
Citations : 293

International Journal of Clinical & Medical Images received 293 citations as per Google Scholar report